lucid.page Reading a dryer correction-factor table, one multiplication at a time
Text size
Read time2 min

# Reading a dryer correction-factor table, one multiplication at a time

Refrigerated dryer catalogs usually publish a nominal capacity at a set of rating conditions, then a table of multipliers for other conditions. The idea is simple: multiply your system flow by the factors for your inlet temperature, ambient temperature and inlet pressure to find the nominal rating you need.

Contents

Here is how that works with one published table. Parker’s SPE selection table gives nominal conditions of 100 psig, 100°F inlet and 100°F ambient. Take a shop with:

The table gives multipliers of 1 (pressure), 1.33 (inlet temperature) and 1 (ambient). Required nominal rating: 50 × 1 × 1.33 × 1 = 66.5 SCFM.

Three cautions go with that number:

  1. The factors belong to that dryer family. A neighboring product line from the same manufacturer uses different factors, and another brand’s dryer needs its own table.
  2. The arithmetic does not settle whether the compressor’s flow figure uses the same reference basis as the dryer rating.
  3. It does not prove that a 75 SCFM model is a fit. The supplier still has to confirm the exact SKU, dew point at your conditions, power and connections.

If a product page gives no correction table at all, the calculation can’t be done honestly. Ask for capacity at your conditions instead.

The air dryer sizing inputs guide walks through the same example along with the questions to send a supplier.

End