# Pints per day only means something next to its test conditions
“70 pints per day” sounds like a fixed property of a dehumidifier. It’s actually one point on a curve. Water removal depends on the temperature and humidity of the air going in, so every pints-per-day figure belongs to a specific test condition.
Contents
One documented example makes this concrete. The Santa Fe Compact70 publishes:
- 70 pints/day at 80°F and 60% relative humidity
- 43.7 pints/day at 65°F and 60% relative humidity
Same unit, two conditions, quite different numbers. Crawl spaces are frequently closer to the cooler point than the warmer one.
How to use this when comparing models:
- Line up published removal at the same temperature and humidity on every model. Don’t compare one unit’s warm-condition figure with another’s cool-condition figure.
- If a model only publishes one point, the others are unknown. Don’t convert with a generic multiplier.
- If an assessor has specified a duty, say 40 pints/day at 65°F and 60%, compare it with the published point at that condition. In the example above, 43.7 meets that stipulated number. It doesn’t prove installed fit or the actual load of the house.
Saturation-condition ratings and cooler-condition ratings describe different air. Reading the condition line first avoids most capacity comparisons going sideways.
The ratings guide at Crawlspace Dehumidifiers keeps each published point with its conditions for the models it covers.